Assumptions.  We all make them.  Last week I discovered an incorrect assumption that we all are happier without.  Most of us want to show the equipment the line is going to or from on our links, right?  It’s a pretty standard request. 

image

For a long time, I’ve said this wasn’t possible. Last week I found out that it is actually really easy!

All you have to do is add an attribute to your link with one of these names:

PROC_FROM, PROC_TO, ACT_FROM, ACT_TO

Here’s an example of a link that I modified:

image

Here’s the link placed in a drawing:

image

What is interesting about this, is that the link is reading the data in the link from the lines table.  Previously, I assumed the links would only read from the Link Database table.  It turns out that the links read and update the information from the Component-Lines table as well!

 

CEDIT Dialog

Process Data dialog

So,  with this easy change, you’ll be able utilize the intelligence of the process lines in your link flags.

Happy Thanksgiving!

Dave Wolfe

Dave WolfeDavid Wolfe is a Process and Power specialist with ECAD who enjoys customizing AutoCAD and CADWorx to make them as efficient as possible.He taught Advanced P&ID courses at CUC 2008 and CUC 2009, and the Introduction to CADWorx P&ID at CUC 2009. In addition he is CADWorx Plant Advanced certified.